The SERIES SD family of PID temperature controllers utilizes today’s advanced technology to provide the value, benefits and accuracy you’ve come to expect from Watlow.The features and performance offered by SERIES SD controllers make them ideally suited for a broad range of applications in
temperature and process control. The SERIES SD single channel controllers include a
universal sensor input with up to three outputs that can be programmed for heat or cool temperature control, or to operate as process or deviation alarms.Programming inverse scaling is also simplified with the user-friendly set-up menu, providing additional value without additional cost. Advanced features of SERIES SD controllers include EIA 485 Modbus™ serial communications, Watlow’s INFOSENSE™
sensor technology, infrared remote communications operation, Watlow’s patented User Definable Menu System and a "Save and Restore" feature that allows the restoration of either factory or user-defined settings.

Available in
1/32,1 /16, 1/8 and 1/4 DIN panel mount sizes,
Watlow’s SERIES SD family is backed by an industry leading three-year warranty from Watlow Winona.The SERIES SD ® ® controllers are UL
and C-UL recognized, CSA and CE certified and include the NEMA 4X (IP65) seal.The
controllers are also available in FM limit approvd versions, and ramping versions.

Line Voltage/Power
Controller
• 100 to 240VÅ(ac), +10/-15 percent; (85-264V~[ac])
• Microprocessor based user-selectable control modes
50/60Hz, ±5 percent
• Single universal input, up to three outputs
• 24V
i(ac/dc), +10/-15 percent; 50/60Hz, ±5 percent
• Control update rates, input = 5Hz, display = 2Hz,
• 10VA maximum power consumption
outputs = 5Hz
• Data retention upon power failure via nonvolatile memory
Operator Interface
Environment
• Dual 4 digit, 7 segment LED displays
• -18 to 65°C (0 to 149°F) operating temperature
• -40 to 85°C (-40 to 185°F) storage temperature
• IRDA infrared port (not available on
/32 DIN)
• 0 to 90 percent RH, non-condensing
• Isolated EIA 485 Modbus™ serial communications
Accuracy
Wiring Termination -Touch Safe Terminals
• Calibration accuracy and sensor conformity: ±0.1 percent
• Input power and control outputs 12 to 22 AWG
of span, ±1°C @ the calibrated ambient temperature and
• Sensor inputs and process outputs 20 to 28 AWG
rated line voltage
• Calibration ambient temperature = 25°C ±3°C (77°F ±5°F)
• Thermocouple, grounded or ungrounded sensors
• Accuracy span: 540°C (1000°F) minimum
• RTD 2- or 3-wire, platinum, 100? @ 0°C calibration to
• Temperature stability: ±0.1°C/°C (±0.2°F/°F) rise in
DIN curve (0.00385 ?/?/°C)
ambient maximum
• Process, 0-20mA @ 100?, or 0-10V
Î(dc) @ 20k? inp
Agency Approvals
impedance
® ®
• UL 3121, C-UL ‚ CSA, CE, NEMA 4X/IP65
• Limit version features FM approval only
 

 